Animal Blood Purification Filter

  • $38.50
Shipping calculated at checkout.


Operation scenarios: 
This product is ideal for blood bank or bed-side transfusions. (100ml/250ml)
Main Features:
  • In compliance with U.S FDA and CE guideline of leuko-reduction filter (WBC < 1x 106 / unit) 
  • The membrane is featured with antibacterial and anti-parasites. (Pore size: 10-15 μm) 
  • The combo design allows more flexibility to the practioner and minimise the contamination risk during transfusion. 
  • Filtration first, then transfusion. The design helps to Minimize the resistance of filter, improving transfusion fluency. 
  • Easy handling, filtration by gravity
Specification: 
  • 1 filter, 1 spike, 1 female luer lock adapter, 1storage container (100mL), and 1 transfusion set
  • Set length: 80 cm
  • Tube diameter: ID 3.0 mm / OD 4.1 mm
  • Drip chamber volume: 20 drops / mL
  • Priming volume: 8 mL
  • Sterile: Ethylene oxide(EtO), nontoxic and nonpyrogenic fluid path  
 
Indication:
The blood purification filter is indicated for the blood transfusion on canine and feline. It is designed for the leukoreduction and the removal of germ and parasites of a single unit of Whole Blood or pRBCs to reduce the risk of occurring adverse transfusion and infectious disease. 

 
Blood conditions:
  • Whole Blood: collected at ambient temperature (20 to 24 ℃) within 8 hours, or refrigerated at 1 to 6 ℃ not later than 7 days after collection.
  • pRBCs: refrigerated at 1 to 6 ℃ for at least 4 hours.  
 
Precautions:

1. Trained personnel only
2. Single use only; do not re-sterilize or reuse
3. Do not use if package is damaged
4. Use the filter immediately when the protective cap is removed
5. The used set should be regarded as biomedical and healthcare waste and discarded in the appropriate place
6. Contains or presence of phthalate: bis (2-ethylhexyl) phthalate (DEHP)
 
  
Instruction for use:
Blood stored in Blood Bag / Storage:
1. Before filtration, evenly and gently shake the blood bag with unfiltered blood unit in case of stratification.
2. Close Clamp A, B, C, D completely.
3. Remove the protective cap and insert the spike into the blood unit.
4. Hang the blood unit up to 150 cm on I.V. pole or hook it to remain vertical.
5. Open Clamp A and C to start gravity infusion.
6. When the blood bag is empty or the flow stops, close Clamp A and C.
7. To store the blood, use sterile tubing welder to seal the tube at seal point A and refrigerate the storage container with filtered blood at 1 to 6 ℃.
 
 Do not use the infusion set after refrigeration.
8. To transfuse directly, please follow "Blood Transfusion Process" to proceed
※ If blood clots slow down the filtration, inject "Normal Saline" or extrude blood bag to break away blood clots.
 
Blood Stored in Syringe / Storage:
1. Before filtration, evenly and gently shake the syringe with unfiltered blood unit in case of stratification.
2. Close Clamp A, B, C, D completely.
3. Attach the syringe with the Female luer lock to prevent overflowing.
4. Open Clamp B and C. to start infusion. When using a syringe injection pump to infuse, please complete the whole process within 3- 5 mins.
5. Close Clamp B and C when the syringe is empty.
6. To store the blood, use sterile tubing welder to seal the tube at seal point A and refrigerate the storage container with filtered blood at 1 to 6 ℃
* Do not use the infusion set after refrigeration.
7. To transfuse directly, please follow “Blood Transfusion Process” to proceed.

Blood Transfusion Process:

1. Evenly and gently shake the storage container with filtered blood unit in case of stratification.

2. Hang the blood unit on I.V. pole or hook it to remain vertical.

3. Attach the administration set to the Male Luer lock adaptor. Open Clamp D and adjust Roller clamp to expel the air within the tubes till the blood flow out, then close the Roller Clamp.

4. Perform venipuncture, adjust the transfusion flow by the Roller clamp.

5. When the transfusion is finished, remove the set and seal the seal point B with sterile tubing welder before disposal.
 
Filtration completion