WIT301V Veterinary Syringe Pump with 3 Years Warranty

  • $939.00
Shipping calculated at checkout.


Main Features

  1. Including 10 kinds working mode: Volume / Simple Rate / Micro / Programme / DOSE Weight / Drug Lab. / Manual Bolus / Auto Bolus
  2. Automatic identification of 5ml, 10ml, 20ml, 30ml, 50ml/60ml, 5 kinds of syringe of different brands.
  3. Automatic the syringe gap fast start function.
  4. Built-in 200 kinds of drugs, covering the clinical use of the drug dose of 54 units on the library, and could be connect with the PC for edit; export & import.
  5. Monitoring and controlling safety technology for the needle loose caused the pressure of syringe rapidly drop.
  6. Support changes the Rate, Time, Dose, VTBI & other important parameters during the pump working.
  7. Advanced pressure detection technology, adjustable 20 level, and two option of units: mmHg / kPa.
  8. With the unique alarm: Pre-alarm of end infuse, Pre-alarm of high pressure block to meet the needs of special treatment
  9. Convenient & flexible combined by 1-3 units pump  

    Standard Package

    • WIT3010V Syringe Pump
    • A/C Adapter
    • User Manual

     Technical Specification:

     

    Working Mode

    Rate/VTBITime/VTBIRate/TimeMicroSimple RateProgrammableDOSE WeightDrug LabAutoBolus, Manual Bolus.

    Syringe

    Open System for 5ml,10ml,20ml,30ml,50ml/60ml 5 kinds of syringe of different brand

    syringe 

    management

    could add / remove / edit / calibrate more than 50 kinds brand syringes

    Accuracy

     ±2%,Built-in: ±1%

    Calibrate

    Automatic or manual calibration of syringe accuracy

    Rate

    5ml syringe: 0.01-150 ml/h
    10ml syringe: 0.01-300 ml/h
    20ml syringe: 0.01-400 ml/h
    30ml syringe: 0.01-600 ml/h
    50ml (60 ml compatible) syringe: 0.01-1200ml/h

    VTBI

    0.1~9999 ml or OFF

    Total Volume Σ

    0-9999.9ml   

    KVO

    0.1~20ml/h Adjustable,Default:1ml/h

    Programmable

    Maximum 8 steps of different syringe rate / time / VTBI

    BOLUS

    Manual Bolus:long Press the Bolus key to infuse and release to stop

    Auto Bolus:short press the Bolus key and set the VTBI & Rate

    Pressure

    200mmHg - 1200mmHg20 level, live pressure displaymmHg & kPa two units

    Pre-Alarm Occlusion

    When the pressure in the tube goes up, it has the function of early warning

    Back off

    The pump will automatic release the pressure of syringe tube after occlusion in case the medical risk.

    Pressure fast drop

    Monitoring and controlling safety for the needle loose caused the pressure of syringe rapidly drop.

    Pre-Alarm Finish

    1 min~30 minThe alarm can be set ahead of VTBI

    Fast start

    First time install the syringe and when the pump start to working, it will automatic remove the

    mechanical gap for high accuracy.

    Parameters Modify

    changes the Rate, Time, Dose, VTBI & other important parameters during the pump working

    Keypad Locker

    Manual / Auto lock keyboard

    History Record

    Record 20000 infuse records, 10000 alarm records, can be downloaded to the computer to save &query

    Self-Test

    safety live time self-test function to ensure the pump working properly

    Alarm

    Occlusion, Finish, Near Finish, Pause timeout, Pusher error, Lower Battery or damage, Motor error, Incorrect syringe type, handle clip error, parameters error and etc. 20 kinds safety monitoring alarm

    Light Tips

    3 color light tips:Green for pump working;Orange for low level alarm (counting working)Red fohigh level alarm (pump stop).

    Voice Tips

    Compliance YY 0709-2009 medical standard, Alarm and key volume level adjustable, with Mute function,

    Monitor

    High brightness color LCDAdjustable brightness

    Communication

    RS485 port, connect with PC to update / download

    AC Power

    AC100V~240V,50Hz/60Hz,25VA

    Battery

    Ni-MH battery, DC9.6V, 2000mAh (after full charged, could continue work more than 7 hours by 5ml/h rate)

    Battery power query

    Live-time query battery life and battery charge status

    Class

    Class I, Type CFIPX4

    Installation

    For round and square pole, Horizontal / Vertical, could superposed 1-3 units

    Dimension

    1.9Kg ,   140mm×145mm×325mm

    Environment

    5℃~40℃;   20%~90% humidity;   70kPa~106kpa atmospheric

    Use Range

    For the patients with constant intravenous infusion of drugs

     